Eaton PROFIBUS-DP EZ204-DP Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Redes Eaton PROFIBUS-DP EZ204-DP. Eaton PROFIBUS-DP EZ204-DP User manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 212
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes

Resumo do Conteúdo

Página 1 - May 2005

For more information visit: www.EatonElectrical.comMN05013001EEZ204-DP PROFIBUS-DP Slave InterfaceUser ManualMay 2005

Página 3 - Dangerous electrical voltage!

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E96Table 43: Byte 4 – 8: Data 1 – 5Winter/summer time, DSTTeleg

Página 4

Read/write date and timeFor more information visit: www.EatonElectrical.comMN05013001E 97Table 44: Byte 4 – 8: Data 1 – 5Byte ContentsValue (hex)4Data

Página 5 - Contents

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E98ExampleThe real-time clock of the EZ800 is to be set to Frid

Página 6

Read/write image dataFor more information visit: www.EatonElectrical.comMN05013001E 99Read/write image dataOverviewJPlease also observe the relevant d

Página 7

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E100Read local inputs IW0This command string enables you to rea

Página 8

Read/write image dataFor more information visit: www.EatonElectrical.comMN05013001E 101Example: Read local inputs IW0The values Data 1 = C4 and Data 2

Página 9

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E102Read inputs of the stations IW1 to IW8The EZ800 and EZD dev

Página 10

Read/write image dataFor more information visit: www.EatonElectrical.comMN05013001E 103Read local analog inputs IA1 to IA4The analog inputs on the EZ8

Página 11 - About This Manual

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E104ExampleA voltage signal is present at analog input 1. The r

Página 12

Read/write image dataFor more information visit: www.EatonElectrical.comMN05013001E 105Read local diagnostics ID1 to ID16The local diagnostics (ID1 –

Página 13 - Device designation

For more information visit: www.EatonElectrical.com 7MN05013001EAbout This ManualTarget readership This manual has been produced for automation techni

Página 14

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E106Table 46: Byte 5 to 6: Data 1 to 2ExampleData 1 = F8, Data

Página 15 - 1 EZ204-DP

Read/write image dataFor more information visit: www.EatonElectrical.comMN05013001E 107Read and write local QW0 outputs/outputs of the stations QW1 to

Página 16 - EZ204-DP

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E108Table 47: Byte5: DataData 1Bit 7 6 5 4 3 2 1 0Q1 0/1Q2 0/1Q

Página 17 - Device setup

Read/write image dataFor more information visit: www.EatonElectrical.comMN05013001E 109Reading and writing local analog output QA1The commands provide

Página 18

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E110Reading local P buttonsThe local P buttons are the display

Página 19 - Improper use

Read/write image dataFor more information visit: www.EatonElectrical.comMN05013001E 111Table 48: Byte 5: DataData 1Bit 7 6 5 4 3 2 1 0P1 0/1P2 0/1P3 0

Página 20

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E112Reading RW.. inputs/SW.. outputs from EZ-LINKThis service a

Página 21 - 2Installation

Read/write image dataFor more information visit: www.EatonElectrical.comMN05013001E 113Table 49: Byte 5 to 6: Data 1 to 2Data 1Bit 7 6 5 4 3 2 1 0RW S

Página 22 - Installation

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E114Value (hex), sent byMaster Slave0 Toggle byteJ page 941 Com

Página 23 - Connecting PROFIBUS-DP

Read/write image dataFor more information visit: www.EatonElectrical.comMN05013001E 115Table 50: Byte 5 to 8: Data 1 to 4Data 1Bit 7 6 5 4 3 2 1 0RN1

Página 24

For more information visit: www.EatonElectrical.com MN05013001E8Device designation This manual uses the following short names for equipment types, as

Página 25 - Electrical isolation

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E116Reading and writing markersTable 51: Byte 2 – 4: Len, Type,

Página 26

Read/write image dataFor more information visit: www.EatonElectrical.comMN05013001E 117Attention!The function blocks and DW markers (32-bit values) of

Página 27 - Maximum distances/bus cable

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E118Example 1 Read marker bit M62Result: Data 1 = 01hex J M62 w

Página 28

Read/write image dataFor more information visit: www.EatonElectrical.comMN05013001E 119Example 2Write marker word MW32 with 823823dec = 337hex J Data

Página 29 - 3 Device Operation

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E120. EZ800 manual search term: MN05013004E. EZD manual search

Página 30 - Device Operation

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 121OverviewOperands Meaning Read/write Type PageA01 – A32

Página 31 - Í or Ú to select CONFIGURATOR

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E122Analog value comparators A01 .. A32Telegram structureByte M

Página 32

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 123Table 52: Operand overviewTable 53: Index 0: Bit IOTab

Página 33 - Status LEDs

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E124Arithmetic function blocks AR01 .. AR32Telegram structureBy

Página 34

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 125Table 55: Operand overviewTable 56: Index 0: Bit IOTab

Página 35 - 4 PROFIBUS-DP Functions

Device designationFor more information visit: www.EatonElectrical.comMN05013001E 9• EZ-AB for– EZ512-AB...– EZ719-AB...• EZ-AC for– EZ512-AC-..– EZ719

Página 36 - PROFIBUS-DP Functions

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E126Block compare function blocks BC01 .. BC32Telegram structur

Página 37 - PROFIBUS certification

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 127Table 58: Operand overviewTable 59: Index 0 – Bit IOTa

Página 38

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E128Block transfer function blocks BT01 .. BT32Telegram structu

Página 39 - Operating Mode

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 129Table 62: Index 0 – Bit IOTable 63: Index 1 - ModeJThe

Página 40 - MN05013001E36

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E130Boolean sequence function blocks BV01 .. BV32Telegram struc

Página 41

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 131Table 64: Operand overviewTable 65: Index 0: Bit IOTab

Página 42 - MN05013001E38

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E132Counters C01 .. C32Telegram structureByte Meaning Value (he

Página 43

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 133Table 67: Operand overviewTable 68: Index 0: Bit IOInd

Página 44 - Example:

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E134Frequency counters CF01 .. CF04Telegram structureByte Meani

Página 45

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 135Table 69: Operand overviewTable 70: Index 0: Bit IOInd

Página 46 - J Table 5 on Page 41

For more information visit: www.EatonElectrical.com MN05013001E10Abbreviations This manual uses abbreviations with the following meanings:hex: Hexadec

Página 47 - 6 Control commands for EZ700

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E136High-speed counters CH01 .. CH04Telegram structureByte Mean

Página 48 - Control commands for EZ700

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 137Table 71: Operand overviewTable 72: Index 0: Bit IOInd

Página 49 - Data exchange procedure

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E138Incremental encoder counters CI01 .. CI02Telegram structure

Página 50

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 139Table 73: Operand overview0Table 74: Index 0 – Bit IOI

Página 51

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E140Comparators CP01 .. CP32Telegram structureByte Meaning Valu

Página 52

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 141Table 75: Operand overviewTable 76: Index 0 – Bit IOIn

Página 53 - (every 12 or 25 ms)

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E142Text output function blocks D01 ..D32Telegram structureByte

Página 54

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 143Table 77: Operand overviewIndex (hex)Operand Read Writ

Página 55

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E144Table 78: Index 0 – Bit IO27 Scaling maximum value 2 ×28 Sc

Página 56

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 145Data function blocks DB01 .. DB32Telegram structureByt

Página 57

For more information visit: www.EatonElectrical.com 11MN05013001E1 EZ204-DPThe EZ204-DP communication module was developed for automation tasks using

Página 58

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E146Table 79: Operand overviewTable 80: Index 0 – Bit IOIndex (

Página 59

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 147PID controllers DC01 .. DC32Telegram structureByte Mea

Página 60

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E148Table 81: Operand overviewIndex (hex)Operand Read Write00 B

Página 61

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 149Table 82: Index 0 – Bit IOTable 83: Index 1 - ModeBit

Página 62

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E150Signal smoothing filters FT01 .. FT32Telegram structureByte

Página 63

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 151Table 84: Operand overviewTable 85: Index 0 – Bit IOIn

Página 64

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E152Receive network data function blocks GT01 .. GT32Telegram s

Página 65

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 153Table 87: Index 0 – Bit IOTable 88: Index 1 – Mode/Par

Página 66

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E1547-day time switches HW01 .. HW32Telegram structureTable 89:

Página 67

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 155Table 90: Index 0 – Bit IOThe data in the following ta

Página 68

For more information visit: www.EatonElectrical.comEZ204-DPMN05013001E12System overview The EZ204-DP slaves are integrated in a PROFIBUS-DP system.Fig

Página 69

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E156Example The channel A parameters of 7-day time switch HW19

Página 70

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 157Year time switches HY01 .. HY32Telegram structureTable

Página 71

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E158Table 93: Index 0 – Bit IOThe data in the following table i

Página 72

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 159Resulting telegram:Bit 7 6 5 4 3 2 1 0 7 6 5 4 3 2 1 0

Página 73

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E160Value scaling function blocks LS01 .. LS32Telegram structur

Página 74

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 161Table 95: Operand overviewTable 96: Index 0 – Bit IOIn

Página 75

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E162Master reset function blocks MR01 .. MR32Telegram structure

Página 76

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 163Table 97: Index 0 – Bit IOTable 98: Index 1 - ModeBit

Página 77

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E164Numerical converters NC01 .. NC32Telegram structureByte Mea

Página 78

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 165Table 99: Operand overviewTable 100: Index 0 – Bit IOT

Página 79

Device setupFor more information visit: www.EatonElectrical.comMN05013001E 13Device setupFigure 2: View of the device PROFIBUS-DP connection, 9-pole

Página 80

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E166Operating hours counters OT01 .. OT04Telegram structureByte

Página 81

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 167Table 102: Operand overviewTable 103: Index 0 – Bit IO

Página 82

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E168Send network data function blocks PT01 .. PT32Telegram stru

Página 83

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 169Table 105: Index 0 – Bit IOBit 7 6 5 4 3 2 1 0FB input

Página 84

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E170Pulse width modulation function blocks PW01 .. PW02Telegram

Página 85 - Timing relays: T1 – T16

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 171Table 106: Operand overviewTable 107: Index 0 – Bit IO

Página 86

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E172Synchronize clock function block SC01Telegram structureTabl

Página 87

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 173Set cycle time function block ST01Telegram structureBy

Página 88

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E174Table 110: Operand overviewTable 111: Index 0 – Bit IOIndex

Página 89 - Year time switch: Y1 – Y8

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 175Timing relays T01 .. T32Telegram structureByte Meaning

Página 90

For more information visit: www.EatonElectrical.comEZ204-DPMN05013001E14Device function description The EZ204-DP module allows the EZ and EZD series d

Página 91 - FB output – – – – – – – Q1

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E176Table 112: Operand overviewTable 113: Index 0 – Bit IOIndex

Página 92

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 177Table 114: Index 1 - Mode/ParametersMode Data 1 Operat

Página 93

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E178Value limitation function blocks VC01 .. VC32Telegram struc

Página 94

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 179Table 115: Operand overviewTable 116: Index 0 – Bit IO

Página 96

For more information visit: www.EatonElectrical.com 181MN05013001EAppendixWhat Happens If ...?Event Explanation RemedyPOW LED not lit No power supply

Página 97 - 7 EZ800/EZD Control Commands

For more information visit: www.EatonElectrical.comAppendixMN05013001E182Overview of commands EZ700The commands are sorted in ascending order:Command

Página 98

Overview of commandsFor more information visit: www.EatonElectrical.comMN05013001E 1831B Write time switch 3 channel B1C Write time switch 3 channel C

Página 99

For more information visit: www.EatonElectrical.comAppendixMN05013001E18437 Read time switch 4 channel A38 Read time switch 4 channel B39Read time swi

Página 100 - EZ800/EZD Control Commands

Overview of commandsFor more information visit: www.EatonElectrical.comMN05013001E 185EZ800/EZDByte 1 Byte 2 Byte 3Date and time Command (hex)Len1 (he

Página 101 - Read/write date and time

Improper useFor more information visit: www.EatonElectrical.comMN05013001E 15EZ800/EZD-CP8..• All markers and EZ-NETdata• Function blocks (read/write,

Página 102

For more information visit: www.EatonElectrical.comAppendixMN05013001E186Byte 1 Byte 2 Byte 3Function blocksCommand (hex)Type (hex)Instance (hex)Read/

Página 103 - Read/write image data

Technical DataFor more information visit: www.EatonElectrical.comMN05013001E 187Technical Data GeneralAmbient temperaturesStandards and regulations EN

Página 104

For more information visit: www.EatonElectrical.comAppendixMN05013001E188Ambient mechanical conditionsElectromagnetic compatibility (EMC)Pollution deg

Página 105

Technical DataFor more information visit: www.EatonElectrical.comMN05013001E 189Dielectric strengthTools and cable cross-sectionsPower supplyLEDsMeasu

Página 106

For more information visit: www.EatonElectrical.comAppendixMN05013001E190PROFIBUS-DPDevice connection SUB-D 9-pole, socketElectrical isolation Bus to

Página 107

DimensionsFor more information visit: www.EatonElectrical.comMN05013001E 191DimensionsFigure 9: Dimensions EZ204-DP (mm)M47.535.57.59010211047.556.562

Página 109

For more information visit: www.EatonElectrical.comMN05013001E 193GlossaryThis glossary refers to subjects relating to PROFIBUS-DP.Acknowledge Acknowl

Página 110

For more information visit: www.EatonElectrical.comGlossaryMN05013001E194Bus terminating resistor Resistor at the beginning and end of a bus line for

Página 111

For more information visit: www.EatonElectrical.comMN05013001E 195EMC Abbreviation for “Electromagnetic Compatibility”. The ability of electrical equi

Página 114

For more information visit: www.EatonElectrical.comGlossaryMN05013001E196I/O Abbreviation for “Input/Output”.Impedance Apparent resistance that a comp

Página 115

For more information visit: www.EatonElectrical.comMN05013001E 197NAMUR Abbreviation for “Normen-Arbeitsgemeinschaft für Mess- und Regeltechnik” (Stan

Página 116

For more information visit: www.EatonElectrical.comGlossaryMN05013001E198Protective conductor A conductor required for the protection against dangerou

Página 117

For more information visit: www.EatonElectrical.comMN05013001E 199Topology Geometric structure of a network or circuit arrangement.UART Abbreviation f

Página 119

For more information visit: www.EatonElectrical.com 201MN05013001EIndex7-day time switchEZ700 ...71

Página 120

For more information visit: www.EatonElectrical.com MN05013001E202Data exchange procedureEZ700 ...

Página 121

For more information visit: www.EatonElectrical.comMN05013001E 203Inputs, network stationsEZ800/EZD, read status ... 102Inv

Página 122

For more information visit: www.EatonElectrical.com MN05013001E204POW LED ... 29Power suppl

Página 123

For more information visit: www.EatonElectrical.comMN05013001E 205Text output function blockRead/write (EZ800/EZD) ... 142Th

Página 124

For more information visit: www.EatonElectrical.com 17MN05013001E2InstallationThe same principles apply as for EZ700, EZ800 and EZD basic units with e

Página 127

© 2005 Eaton CorporationAll Rights ReservedPrinted in USAPublication No. MN05013001EMay 2005Eaton Electrical1000 Cherrington ParkwayMoon Township, PA

Página 128

For more information visit: www.EatonElectrical.comInstallationMN05013001E18Figure 4: Connection between basic unit and EZ204-DPConnecting the power s

Página 129

Connecting PROFIBUS-DPFor more information visit: www.EatonElectrical.comMN05013001E 19Connecting PROFIBUS-DP Use a 9-pole SUB-D plug to connect the P

Página 130

For more information visit: www.EatonElectrical.comInstallationMN05013001E20Bus terminating resistors The first and last station in a bus segment must

Página 131

Electrical isolationFor more information visit: www.EatonElectrical.comMN05013001E 21Electrical isolation The following electrical isolation should be

Página 132

For more information visit: www.EatonElectrical.comInstallationMN05013001E22Transfer rates – automatic baud rate detectionThe EZ204-DP module automati

Página 133

Maximum distances/bus cableFor more information visit: www.EatonElectrical.comMN05013001E 23Distance between stations when using Type A cable to IEC 6

Página 135

For more information visit: www.EatonElectrical.com 25MN05013001E3 Device OperationInitial power up XBefore you switch on the device, verify that it i

Página 136

For more information visit: www.EatonElectrical.comMN05013001E IBefore commencing the installation• Disconnect the power supply of the device.• Ensure

Página 137 - 2147483648 to

For more information visit: www.EatonElectrical.comDevice OperationMN05013001E26Setting the PROFIBUS-DP station addressEvery PROFIBUS-DP station requi

Página 138

Setting the PROFIBUS-DP stationFor more information visit: www.EatonElectrical.comMN05013001E 27XEnter the System menu by pressing DEL + ALT simultane

Página 139

For more information visit: www.EatonElectrical.comDevice OperationMN05013001E28EZ700 devices show the following dialog immediately:Information on the

Página 140

Status LEDsFor more information visit: www.EatonElectrical.comMN05013001E 29Status LEDs The EZ204-DP expansion unit has two LEDs.POW LED, FunctionFigu

Página 141 - –2147483648 to

For more information visit: www.EatonElectrical.comDevice OperationMN05013001E30Cycle time of EZ basic unit Communication between the basic unit and E

Página 142

For more information visit: www.EatonElectrical.com 31MN05013001E4 PROFIBUS-DP FunctionsSlave modules The EZ204-DP expansion module is a PROFIBUS-DP s

Página 143

For more information visit: www.EatonElectrical.comPROFIBUS-DP FunctionsMN05013001E32Diagnostics data The EZ204-DP device features the standard diagno

Página 144

PROFIBUS certificationFor more information visit: www.EatonElectrical.comMN05013001E 33PROFIBUS certification EZ204-DP was certified as a PROFIBUS-DP

Página 146

For more information visit: www.EatonElectrical.comMN05013001E 355 Inputs/Outputs, EZ700/800/EZD Operating ModeThe appropriate module must be selected

Página 147

For more information visit: www.EatonElectrical.com MN05013001EII• Emergency stop devices complying with IEC/EN 60204-1 must be effective in all opera

Página 148

For more information visit: www.EatonElectrical.comInputs/Outputs, EZ700/800/EZD Operating ModeMN05013001E36“Inputs 3 bytes” module: operating mode, S

Página 149 - Telegram structure

“Inputs 3 bytes” module: operating mode, S1 – S8For more information visit: www.EatonElectrical.comMN05013001E 37Table 2: Byte 1: Status of S1 to S8 o

Página 150

For more information visit: www.EatonElectrical.comInputs/Outputs, EZ700/800/EZD Operating ModeMN05013001E38“Inputs 1 byte” module: S1 –S8When this mo

Página 151 - PID controllers DC01 .. DC32

“Outputs 3 bytes” module: operating mode, R9For more information visit: www.EatonElectrical.comMN05013001E 39Table 3: Byte 0: Operating mode0 = status

Página 152

For more information visit: www.EatonElectrical.comInputs/Outputs, EZ700/800/EZD Operating ModeMN05013001E40Table 4: Byte 1: Write status of R9 to R16

Página 153

“Outputs 3 bytes” module: operating mode, R9For more information visit: www.EatonElectrical.comMN05013001E 41Table 5: Byte 2: Write status of R1 to R8

Página 154

For more information visit: www.EatonElectrical.comInputs/Outputs, EZ700/800/EZD Operating ModeMN05013001E42“Outputs 1 byte” module: R1–R8When this mo

Página 155

For more information visit: www.EatonElectrical.com 43MN05013001E6 Control commands for EZ700 Data exchange procedure The “Control commands 9 bytes” m

Página 156

For more information visit: www.EatonElectrical.comControl commands for EZ700MN05013001E44The master initiates the data exchange of the control comman

Página 157 - (designation of PUT FB

Data exchange procedureFor more information visit: www.EatonElectrical.comMN05013001E 45The following tables show the different control commands possi

Página 158

For more information visit: www.EatonElectrical.com 1MN05013001EContentsAbout This Manual...7Target

Página 159

For more information visit: www.EatonElectrical.comControl commands for EZ700MN05013001E46Table 6: Index 0 – date and time of real-time clockTable 7:

Página 160

Data exchange procedureFor more information visit: www.EatonElectrical.comMN05013001E 47Table 8: Index 2 – Winter time (only valid if Area = “Rule” se

Página 161

For more information visit: www.EatonElectrical.comControl commands for EZ700MN05013001E48Table 9: Switching rule bit arrayData 5 Data 4 Data 3 Data 2

Página 162

Read/write image dataFor more information visit: www.EatonElectrical.comMN05013001E 49Read/write image dataGeneral notes on working with image dataWhe

Página 163 - Resulting telegram:

For more information visit: www.EatonElectrical.comControl commands for EZ700MN05013001E50OverviewOperands Meaning Read/writeType PageA1 – A16 Analog

Página 164

Read/write image dataFor more information visit: www.EatonElectrical.comMN05013001E 51Analog value comparators/threshold comparators: A1–A16The follow

Página 165

For more information visit: www.EatonElectrical.comControl commands for EZ700MN05013001E52Counters: C1 – C16The following commands are used to read th

Página 166

Read/write image dataFor more information visit: www.EatonElectrical.comMN05013001E 53Text function blocks: D1 – D16The following commands are used to

Página 167

For more information visit: www.EatonElectrical.comControl commands for EZ700MN05013001E54Local inputs: I1 – I16This command string enables you to rea

Página 168

Read/write image dataFor more information visit: www.EatonElectrical.comMN05013001E 55Table 13: Byte 5 to 6: Data 1 to 2Data 1Bit 7 6 5 4 3 2 1 0I1 0/

Página 169

For more information visit: www.EatonElectrical.comContentsMN05013001E24 PROFIBUS-DP Functions...31Slave modules

Página 170

For more information visit: www.EatonElectrical.comControl commands for EZ700MN05013001E56Local analog inputs: IA1 – IA4The analog inputs on the EZ700

Página 171

Read/write image dataFor more information visit: www.EatonElectrical.comMN05013001E 57Example:A voltage signal is present at analog input 1. The requi

Página 172

For more information visit: www.EatonElectrical.comControl commands for EZ700MN05013001E58Markers: M1 – M16/N1 – N16Telegram structureByte Meaning Val

Página 173

Read/write image dataFor more information visit: www.EatonElectrical.comMN05013001E 59Example:Marker M13 is set.Byte Meaning Value (hex), sent byMaste

Página 174

For more information visit: www.EatonElectrical.comControl commands for EZ700MN05013001E60Markers: M1 – M16/N1 – N16Unlike the write operation, the ma

Página 175

Read/write image dataFor more information visit: www.EatonElectrical.comMN05013001E 61Table 15: Byte 5 to 6: Data 1 to 2Example:The N markers are read

Página 176

For more information visit: www.EatonElectrical.comControl commands for EZ700MN05013001E62Operating hours counters: O1 – O4The following commands are

Página 177

Read/write image dataFor more information visit: www.EatonElectrical.comMN05013001E 63Local P buttons: P1 – P4The local P buttons are the display curs

Página 178

For more information visit: www.EatonElectrical.comControl commands for EZ700MN05013001E64Table 17: Byte 5: Data 1Example:Data 1 = 2hex J P3 is active

Página 179 - Timing relays T01 .. T32

Read/write image dataFor more information visit: www.EatonElectrical.comMN05013001E 65Local outputs: Q1 – Q8The local outputs can be read directly via

Página 180

For more information visit: www.EatonElectrical.comMN05013001E 3– Analog value comparator/threshold comparator: A1 – A16 ...

Página 181

For more information visit: www.EatonElectrical.comControl commands for EZ700MN05013001E66Inputs/outputs of EZ-LINK: R1–R16/S1–S8This service allows y

Página 182

Read/write image dataFor more information visit: www.EatonElectrical.comMN05013001E 67Table 19: Byte 5 to 6: Data 1 to 2Data 1Bit 7 6 5 4 3 2 1 0RW SW

Página 183

For more information visit: www.EatonElectrical.comControl commands for EZ700MN05013001E68Timing relays: T1 – T16The following commands are used to re

Página 184

Read/write image dataFor more information visit: www.EatonElectrical.comMN05013001E 69Year time switch: Y1 – Y8The following commands are used to read

Página 185 - Appendix

For more information visit: www.EatonElectrical.comControl commands for EZ700MN05013001E70Master reset: Z1 – Z3Telegram structureTable 22: Byte 5: Dat

Página 186

Read/write image dataFor more information visit: www.EatonElectrical.comMN05013001E 717-day time switch: ö1 – ö8The following commands are used to rea

Página 187 - Overview of commands

For more information visit: www.EatonElectrical.comControl commands for EZ700MN05013001E72Read/write function block dataGeneral notesAlways note the f

Página 188

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 73Analog value comparator/threshold comparator: A1–A16Tel

Página 189

For more information visit: www.EatonElectrical.comControl commands for EZ700MN05013001E74Table 24: Operand overviewIndex (hex)Operand Read Write00 Pa

Página 190

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 75Table 25: Index 00 – ParametersExample: Data 1 (Byte 5)

Página 191 - Technical Data

For more information visit: www.EatonElectrical.comContentsMN05013001E4– Text output function blocks D01 ..D32 ...142– Data function blo

Página 192

For more information visit: www.EatonElectrical.comControl commands for EZ700MN05013001E76Counter relays: C1 – C16Telegram structureByte Meaning Value

Página 193

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 77Table 27: Operand overviewTable 28: Index 00 – Paramete

Página 194

For more information visit: www.EatonElectrical.comControl commands for EZ700MN05013001E78Table 29: Index 01 – Control byteExample:the actual value of

Página 195 - Dimensions

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 79Operating hours counters: O1 – O4Telegram structureTabl

Página 196

For more information visit: www.EatonElectrical.comControl commands for EZ700MN05013001E80Table 31: Index 00 – ParametersExample:Data 1 (Byte 5) = 0x0

Página 197 - Glossary

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 81Timing relays: T1 – T16Telegram structureByte Meaning V

Página 198

For more information visit: www.EatonElectrical.comControl commands for EZ700MN05013001E82Table 33: Operand overviewIndex (hex)Operand Read Write00 Pa

Página 199

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 83Table 34: Index 00 – ParametersExample:Data 1 (Byte 5)

Página 200

For more information visit: www.EatonElectrical.comControl commands for EZ700MN05013001E84Table 35: Index 01 – Control byteExample:The time setpoint 1

Página 201

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 85Year time switch: Y1 – Y8Telegram structureByte Meaning

Página 202

For more information visit: www.EatonElectrical.comMN05013001E 5Glossary ...193Index ..

Página 203

For more information visit: www.EatonElectrical.comControl commands for EZ700MN05013001E86Table 36: Operand overviewTable 37: Index 00 – ParametersExa

Página 204

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 87Table 38: Index 01 – Control byteChannel A, Index 11/12

Página 205

For more information visit: www.EatonElectrical.comControl commands for EZ700MN05013001E887-day time switch: Ö1 – Ö8Telegram structureByte Meaning Val

Página 206

Read/write function block dataFor more information visit: www.EatonElectrical.comMN05013001E 89Table 39: Operand overviewIndex (hex)Operand Read Write

Página 207

For more information visit: www.EatonElectrical.comControl commands for EZ700MN05013001E90Table 40: Index 00 – ParametersExample:Data 1 (Byte 5) = 0x0

Página 208

Analysis – error codes via EZ-LINKFor more information visit: www.EatonElectrical.comMN05013001E 91Analysis – error codes via EZ-LINKThe EZ700 basic u

Página 209

For more information visit: www.EatonElectrical.comControl commands for EZ700MN05013001E92Table 42: Error codesError codeDescription0x01 Unknown teleg

Página 210

For more information visit: www.EatonElectrical.com 93MN05013001E7 EZ800/EZD Control CommandsData exchange procedure The Control commands 9 bytes modu

Página 211

For more information visit: www.EatonElectrical.comEZ800/EZD Control CommandsMN05013001E94Byte 0 – Toggle byteByte 0 is used to activate the sending o

Página 212 - Publication No. MN05013001E

Read/write date and timeFor more information visit: www.EatonElectrical.comMN05013001E 95Read/write date and timeTelegram structureJPlease also note t

Comentários a estes Manuais

Sem comentários